# Server.Monitor.StoreClientHWInfo

Save hardware identification data from client interrogation as
client metadata.

The primary use case is to store a stable device serial number as
the `serial` metadata field. Indexing `serial` makes clients quickly
searchable from the GUI by their hardware identity. Additional
hardware fields, like manufacturer, product name and model, may also
be set as metadata for non-indexed lookup.

## Setup requirement

This artifact reads from a source named `HWIdentification` (override
via `HWIdentificationSource`) inside the interrogation artifact named
by `InterrogationArtifact` (default: your `Custom.` override of
`Generic.Client.Info`).
You need to add a source by that name to your
[`Generic.Client.Info`](/artifact_references/pages/generic.client.info/)
override that calls
[`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/):

```yaml
- name: HWIdentification
  query: SELECT * FROM Artifact.Generic.Client.HW.Identification()
```

## Stable serial selection

Hardware serials are reported under several names depending on the
vendor and platform: `product_serial`, `board_serial`,
`chassis_serial`, `firmware_serial`. Some are reliable; others are
blank or contain BIOS placeholders such as `Default string` or
`System Serial Number`. `SerialColumn` lets you declare a fallback
order: the first candidate with a non-empty, non-ignored (by
`SerialIgnore`) value is picked. `SerialIgnore` is a regex that filters
out known placeholder values.


## Customization

Use `HWInfoMetadata` to select which hardware information to store,
and under what name, e.g.

| Field | Alias |
| ----- | ----- |
| `board_manufacturer` | `manufacturer`
| `product_name` | |
| `virtual` | |
| `chassis_asset_tag` | `asset_tag` |

If you modify/extend
[`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/),
remember to still produce a single row, and simply add new columns
to refer to in `HWInfoMetadata`.

If you need to store results from collections other than hardware
information like
[`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/),
use
[`Server.Monitor.StoreClientInfo`](/exchange/artifacts/pages/server.monitor.storeclientinfo/)
instead.

## See also

- [`Server.Monitor.StoreClientInfo`](/exchange/artifacts/pages/server.monitor.storeclientinfo/):
  sibling artifact for storing arbitrary metadata from any
  interrogation source (no serial-specific behavior)
- [`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/):
  the producing artifact this one expects to consume
- [How can I automatically add & update client metadata?](/knowledge_base/tips/automating_metadata/):
  in-depth walkthrough about how to save interrogation data as
  client metadata

#metadata #automation


---

````yaml
name: Server.Monitor.StoreClientHWInfo
author: Andreas Misje – @misje
description: |
  Save hardware identification data from client interrogation as
  client metadata.

  The primary use case is to store a stable device serial number as
  the `serial` metadata field. Indexing `serial` makes clients quickly
  searchable from the GUI by their hardware identity. Additional
  hardware fields, like manufacturer, product name and model, may also
  be set as metadata for non-indexed lookup.

  ## Setup requirement

  This artifact reads from a source named `HWIdentification` (override
  via `HWIdentificationSource`) inside the interrogation artifact named
  by `InterrogationArtifact` (default: your `Custom.` override of
  `Generic.Client.Info`).
  You need to add a source by that name to your
  [`Generic.Client.Info`](/artifact_references/pages/generic.client.info/)
  override that calls
  [`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/):

  ```yaml
  - name: HWIdentification
    query: SELECT * FROM Artifact.Generic.Client.HW.Identification()
  ```

  ## Stable serial selection

  Hardware serials are reported under several names depending on the
  vendor and platform: `product_serial`, `board_serial`,
  `chassis_serial`, `firmware_serial`. Some are reliable; others are
  blank or contain BIOS placeholders such as `Default string` or
  `System Serial Number`. `SerialColumn` lets you declare a fallback
  order: the first candidate with a non-empty, non-ignored (by
  `SerialIgnore`) value is picked. `SerialIgnore` is a regex that filters
  out known placeholder values.


  ## Customization

  Use `HWInfoMetadata` to select which hardware information to store,
  and under what name, e.g.

  | Field | Alias |
  | ----- | ----- |
  | `board_manufacturer` | `manufacturer`
  | `product_name` | |
  | `virtual` | |
  | `chassis_asset_tag` | `asset_tag` |

  If you modify/extend
  [`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/),
  remember to still produce a single row, and simply add new columns
  to refer to in `HWInfoMetadata`.

  If you need to store results from collections other than hardware
  information like
  [`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/),
  use
  [`Server.Monitor.StoreClientInfo`](/exchange/artifacts/pages/server.monitor.storeclientinfo/)
  instead.

  ## See also

  - [`Server.Monitor.StoreClientInfo`](/exchange/artifacts/pages/server.monitor.storeclientinfo/):
    sibling artifact for storing arbitrary metadata from any
    interrogation source (no serial-specific behavior)
  - [`Generic.Client.HW.Identification`](/exchange/artifacts/pages/generic.client.hw.identification/):
    the producing artifact this one expects to consume
  - [How can I automatically add & update client metadata?](/knowledge_base/tips/automating_metadata/):
    in-depth walkthrough about how to save interrogation data as
    client metadata

  #metadata #automation

type: SERVER_EVENT

parameters:
  - name: InterrogationArtifact
    type: regex
    description: |
      Name of the client artifact to watch
    default: Custom.Generic.Client.Info

  - name: HWIdentificationSource
    description: |
      Source in InterrogationArtifact that contains hardware information
    default: HWIdentification

  - name: SerialColumn
    description: |
      Name of column containing the serial number used to find the device in
      Snipe-IT. The default behavior is to pick the first non-empty value in
      product_serial, board_serial, and lastly, firmware_serial. The order of
      choices matter.
    type: multichoice
    choices:
      - product_serial
      - board_serial
      - chassis_serial
      - firmware_serial
    default: '["product_serial", "board_serial", "firmware_serial"]'

  - name: SerialMetadataField
    description: |
      Name of the metadata field that will store the serial number (from
      SerialColumn).
    default: serial

  - name: SerialIgnore
    description: |
      Serial values to ignore, typically defaults set on motherboards.
    type: regex
    default: '^(System Serial Number|System Version|Default string|0|None|)$'

  - name: HWInfoMetadata
    description: |
      Additional columns from InterrogationArtifact/HWIdentificationSource that will be
      set as client metadata (SerialColumn/SerialMetadataField is always set).
      Specify the column from the HWIdentification source in "Field", and an
      optional alias, used as metadata name, in "Alias".
    type: csv
    default: |
      Field,Alias
      board_manufacturer,manufacturer
      product_name,

  - name: KeepEmptyValues
    description: |
      If true, an empty value will be stored as metadata. If false, the metadata
      will not be set at all. Note that if a metadata value was previously empty,
      this will not remove that value. Empty/null serials are ignored.
    type: bool
    default: false

sources:
  - query: |
      LET HWInfo = SELECT *
        FROM foreach(row={
          SELECT *
          FROM watch_monitoring(artifact='System.Flow.Completion')
          WHERE Flow.artifacts_with_results =~ InterrogationArtifact
        },
                     query={
          SELECT ClientId,
                 *
          FROM source(client_id=ClientId,
                      flow_id=Flow.session_id,
                      artifact=InterrogationArtifact,
                      source=HWIdentificationSource)
        })

      // With HW info as dict:
      LET HWInfoDict = SELECT _value.ClientId AS ClientId,
                              _value - dict(ClientId=NULL, _Source=NULL) AS Data
        FROM items(item={ SELECT * FROM HWInfo })

      // Walk SerialColumn in declared priority order and return the first
      // candidate field in Data with a non-empty, non-ignored value.
      LET SerialValue(Data) = SELECT Value
        FROM foreach(row=SerialColumn,
                     query={
          SELECT get(item=Data, field=_value) AS Value
          FROM scope()
        })
        WHERE Value
         AND NOT str(str=Value) =~ SerialIgnore
        LIMIT 1

      LET NullOrEmpty(Value) = Value = NULL OR Value = ""

      LET SelectedMetadata = SELECT *
        FROM foreach(row=HWInfoDict,
                     query={
          SELECT ClientId,
                 to_dict(item={
          SELECT *
          FROM foreach(row=HWInfoMetadata,
                       query={
          SELECT Alias || Field AS _key,
                 get(item=Data, field=Field) AS _value
          FROM scope()
          WHERE KeepEmptyValues OR (_value != NULL
             AND len(list=str(str=_value)))
        })
        }) + if(condition=NOT NullOrEmpty(Value=SerialValue(Data=Data)[0].Value),
                then=set(item=dict(),
                         field=SerialMetadataField,
                         value=SerialValue(Data=Data)[0].Value),
                else=dict()) AS Metadata
          FROM scope()
        })

      // Set the metadata and return the dict of data, as well as the
      // client_set_metadata() result:
      // Do not store an empty dict. This has proved to cause issues:
      LET SetMetadata = SELECT *, if(condition=Metadata,
                                     then=client_set_metadata(
                                       client_id=ClientId,
                                       metadata=Metadata),
                                     else=false) AS Updated
        FROM SelectedMetadata

      SELECT *
      FROM SetMetadata````